This is a sample Portal for a fictional home.PCRA clients: sign in to your Portal →
Property Condition Risk Assessment
PCRA · PROPERTY CONDITION & RISK ASSESSMENT
742 Evergreen Terrace · Brookfield, IL 60513
PCRA Demonstration Home · Baseline #1 · 02-28-2026
PCRA Home Hub

Welcome Home, Kelly

742 Evergreen Terrace · Brookfield, IL 60513
This is your home base. Start here, then go wherever you need to go.
Tʜᴇᴀ is here with you.Portal Assistant

Ask naturally. I’ll work with the information already in your Portal and bring the relevant parts of your home forward.

ASK Tʜᴇᴀ

HOME HUBChoose a direction above. The Property Record opens below.
What needs attention
22reportable items imported
1 Major Improvement 14 General Repairs 6 Minor Repairs 1 Specific Limitation
Professional baseline

Assessment #1

Published ScribeWare report established the starting professional record for this property.
Current priority lens

Safety + Water First

Electrical breaker sizing, water-heater venting, attic moisture indicators, grading, plumbing leaks and drainage-related items rise first.
Home Hub › Living Spaces & Rooms

Rooms imported from ScribeWare

Living Room, Entry and Stairs

Drywall · Tile/Hardwood · Metal door · Casement windows · Forced air

Air supply vents dirty throughout
Minor Repair · LS-1
Dirty supply vents were reported throughout; cleaning was recommended to improve heating/cooling efficiency.
Window cranks do not function properly
Minor Repair · LS-2
Butterfly cranks throughout the property were reported stripped, oversized or improperly fastened.
Family Room

Drywall · Hardwood · Casement windows · Forced air

Screens missing
Minor Repair · LS-3
Missing window screens were documented.
Ceiling-fan remote not functioning properly
Minor Repair · LS-4
Ceiling-fan remote operation was deficient.
Bathrooms
Master-bath window hardware not functioning properly
General Repair · B2-2
Repair or replacement was recommended to restore proper window operation.
Tub/shower diverter valve not functioning properly
General Repair · B2-3
Water continued to discharge from the showerhead when the tub faucet was selected.
Plumbing leaks / slow drainage
Minor Repairs · B2-4, B2-5, B2-6
Leaks, slow drainage and a leaking shower head were documented in multiple bathrooms.
Laundry
Rubber washer hoses
Minor Repair · L-1
Replace aging rubber washer hoses with braided supply lines; an automatic shutoff was also recommended.
Home Hub › Home Systems

Major components and current findings

Electrical — Main Panel

Square D · 200 amps · conduit branch circuits · plumbing ground + grounding rod

Conductors improperly sized to breakers
General Repair · E-1 · Fire & Life Safety Risk
Evaluation and correction by a qualified electrician was recommended because conductor and breaker sizing did not match properly.
Plumbing — Water Heater

Bradford White · Natural gas · ~3–5 years estimated · 40 gal

Orphaned water heater
General Repair · P-1 · Fire & Life Safety · Carbon Monoxide Risk
The high-efficiency furnace now vents directly outdoors, leaving the water heater to vent up the chimney alone. The report recommended power venting or an appropriate chimney liner.
Heating — Furnace

Lennox · 2013 · Forced air · ~13 years old

Humidifier leaks / stains
General Repair · H-1
Water leakage and staining were documented at the furnace-mounted humidifier.
Humidifier drain tubing dirty/soiled
Minor Repair · H-2
Replacement was recommended as part of humidifier servicing.
High-efficiency furnace condensate drain leaking
General Repair · H-3
Repair the condensate drain and confirm proper drainage.
Exterior intake/exhaust screening missing
General Repair · H-4
Screening was recommended subject to manufacturer requirements so animals cannot enter or nest.
Air Conditioning — Condenser

Lennox · 2013 · Central air · ~3–3.5 tons estimated · west exterior

Sump

Submersible · acrylic pit · PVC discharge · check valve present · battery backup not present

Home Hub › Maintenance

Care generated from the baseline

Washer supply hoses — Completed 03-23-2026
D-010 · Maintenance · Homeowner documented
Rubber hoses were replaced with braided supply lines. A later recurrence/check remains part of the living record.
HVAC / humidifier service — Overdue, then completed 07-29-2026
D-011 · Maintenance · Contractor documented
Seasonal service progressed from upcoming to due to overdue before completion was documented.
Roof flashing repair — Completed and verified
D-005 · Repair → Verification
Repair activity was documented after the baseline and later PCRA verification was added to the record.
Attic insulation improvement — Scheduled
D-008 · Planning / Maintenance
Insulation improvement moved from baseline recommendation into homeowner planning and scheduling.
Radon testing every two years recommended
Existing mitigation system noted
The baseline documented a radon system and periodic testing recommendation.
Home Hub › Improvements & Planning

Projects worth planning

Attic dark surface / moisture-related condition
Major Improvement · A-1
Dark staining on framing/sheathing may be consistent with organic growth associated with elevated moisture conditions. Evaluation of moisture sources and ventilation was recommended.
Increase attic insulation
General Repair · A-3
Insulation levels were reported below current recommended standards; increasing to approximately R-49 was recommended.
Correct negative grading
General Repair · E1-3
Grading slopes toward the house in areas and should be corrected to promote drainage away from the foundation.
HR-001 — Basement dampness reported 04-15-2026
Homeowner Reported · Related to D-003 / D-004 · Causation not established
The homeowner reported dampness after the baseline. The Portal relates the report to existing water-management records while preserving the distinction between homeowner reporting and professional assessment.
Home Hub › Records & History

Property timeline

02-28-2026 — Baseline Assessment #1
PCRA assessed · 28 baseline records
The professional baseline established the starting condition of the Demonstration Home.
03-07-2026 — Exterior locks changed
D-017 · Homeowner documented · Completed
Ownership guidance moved from recommendation to completed homeowner activity.
03-13-2026 — Electrical correction verified
D-001 · Contractor documented → PCRA verified
The conductor/breaker mismatch was corrected and the professional verification became part of the record history.
03-23-2026 — Washer hoses replaced
D-010 · Homeowner documented · Completed
Braided supply lines replaced the baseline rubber hoses.
04-15-2026 — Homeowner reported basement dampness
HR-001 · Homeowner reported
A new homeowner-generated observation was added and related to grading/foundation records D-003 and D-004. The relationship does not assert causation.
05-01-2026 — Grading correction documented
D-003 · Contractor documented
Drainage correction activity was added without rewriting the original baseline condition.
05-26-2026 — HVAC service became due
D-011 · Maintenance status progression
The living record advanced the maintenance state based on time.
07-10-2026 — HVAC service overdue
D-011 · Maintenance status progression
The record preserved the overdue state and associated risk context.
07-29-2026 — HVAC service completed
D-011 · Contractor documented
Completion was added as a new event rather than deleting the earlier due/overdue history.
08-13-2026 — Roof flashing repair verified
D-005 · PCRA verified
The repair and later verification remain linked to the original baseline record.
08-25-2026 — Attic insulation improvement scheduled
D-008 · Homeowner documented · Planned
The recommendation progressed into an active project.
09-07-2026 — Interim professional review
PCRA reviewed
Current conditions were reviewed against, but not determined by, Baseline #1 and subsequent Portal activity.
09-24-2026 — Washer-hose follow-up / recurrence check
D-010 · Maintenance history
The completed maintenance item remained available for later follow-up instead of disappearing from the record.
Home Hub › Risk & Insurance

Priority risk lenses

Electrical fire / life-safety exposure
E-1
Improper conductor-to-breaker sizing was identified at the main panel.
Combustion / carbon-monoxide exposure
P-1
Orphaned water-heater venting configuration was identified.
Water / moisture exposure
A-1 · E1-3 · plumbing leaks
Attic staining, negative grading and multiple plumbing leaks create a consistent water-control theme.
Garage safety
G-1
Automatic service door opener did not reverse when travel was obstructed.
Ownership Guidance

Imported homeowner guidance

Change exterior door locks after taking ownershipRekey exterior entry points and update keypad/access credentials.
Identify and label utility shutoffs and controlsMake sure household members know where critical shutoffs are and how they operate.
Understand smoke-alarm sensing typesPhotoelectric and ionization technologies respond differently to fire conditions.
\n\n\n